Access Controllers

      Software

      Mifare Readers

      Accessories

      Cards and Key tags

      Parking Systems

      Downloads

 


System Features

Support Mifare or ISO14443 Type A card
Operating: Mifare Card Serial Number
Weigand 24/34 interface
Water proof design
RF8504 is for surface mounting

Technical Specifications

Card Format: Mifare S50 1KB or compatible
Dimension: 87mm × 109mm × 31mm
Hole diameter: 75mm
DC Power: 7 - 15VDC
Static Current: 50mA, Operating Current: 60mA.
Temperature: - 25 ~ 70 Degrees
Humidity: 10% ~ 90%
Weight: 200g
Reader range: 4-6cm
Output: Wiegand 26/34 bits

Connection Pin Assignment

Controller Wire No.
Reader wire color
Wiegand 26/34 bits wire definition
1
Black
Ground (GND)
2
Orange
Hold
3
Blue
Green LED
4
Green
Data0 (Data)
5
White
Data1 (CLK)
6
Brown
BUZZER (buzzer control)
7
Red
Power supply (VCC): 7 -15VDC

Note:
The connection between reader and controller should use the 8 cores STP. The diameter should over 24AWG(0.206mm²), the distance should be less than 100M.

To transmit the data successfully, the data0 and data1 should use the wire in the same pair. E.g. Green, Green/white.
When the transmitting distance is over 60M, we should combine the wires to connect Data0 and Data1, this is for reduce the resistance.
Do not use the same source of power supply for the electrical door lock and readers to avoid electrical sparkle interference.

Installation for Surface mounting

Drill into the wall for 2 holes (diameter=6mm, depth=32mm), and drill for another hole of 1/2 inch.
Drill the reader's wire through the hole, and use screw (6*22mm) to peg the reader base..
Cover the reader module into reader base. When you hear "Ka", it's OK.

 